{"id":615070,"date":"2026-09-22T23:12:31","date_gmt":"2026-09-22T23:12:31","guid":{"rendered":"https:\/\/www.olympiajournal.com\/news\/story\/615070\/exs6011t-series-explosionproof-dual-temperature-switch-advances-industrial-temperature-control.html"},"modified":"2026-09-22T23:12:31","modified_gmt":"2026-09-22T23:12:31","slug":"exs6011t-series-explosionproof-dual-temperature-switch-advances-industrial-temperature-control","status":"publish","type":"post","link":"https:\/\/www.olympiajournal.com\/news\/story\/615070\/exs6011t-series-explosionproof-dual-temperature-switch-advances-industrial-temperature-control.html","title":{"rendered":"ExS6011-T Series Explosion-Proof Dual Temperature Switch Advances Industrial Temperature Control"},"content":{"rendered":"<p style=\"text-align: justify\">Beijing China-September 22, 2026<\/p>\n<p style=\"text-align: justify\">I. Product Positioning<\/p>\n<p style=\"text-align: justify\">The <a rel=\"nofollow\" href=\"https:\/\/www.soloonactuators.com\/exs6011-t-dual-temperature-switch-product\/\">ExS6011-T series explosion-proof dual temperature switch<\/a> is specifically designed for workplaces with explosive hazardous gases, vapors, or combustible dust, such as oil and petrochemical facilities. Used in conjunction with explosion-proof damper actuators, it provides overtemperature safety protection for damper systems.<\/p>\n<p style=\"text-align: justify\">The product holds three major certifications: China Explosion-Proof Certification, EU ATEX Certification, and International IECEx Certification, allowing installation in major hazardous areas worldwide.<\/p>\n<p style=\"text-align: justify\">&nbsp;<\/p>\n<p style=\"text-align: justify\">II. Key Features Two optional actuation temperatures: 72\u2103 or 150\u2103, adapting to different process scenarios<\/p>\n<p style=\"text-align: justify\">&nbsp;<\/p>\n<p style=\"text-align: justify\">Universal power supply: supports AC\/DC 24V and AC 110&ndash;240V<\/p>\n<p style=\"text-align: justify\">&nbsp;<\/p>\n<p style=\"text-align: justify\">High protection rating IP66: dust-tight and protected against powerful water jets, suitable for outdoor and harsh conditions<\/p>\n<p style=\"text-align: justify\">&nbsp;<\/p>\n<p style=\"text-align: justify\">Explosion-proof marking: Ex db \u2161C T6 Gb \/ Ex tb \u2162C T85\u2103 Db &mdash; covers Zone 1\/Zone 2 gas hazardous areas and Zone 21\/Zone 22 dust hazardous areas, meeting the highest safety grades<a rel=\"nofollow\" href=\"https:\/\/www.soloonactuators.com\/uploads\/ExS6011-T-series-explosion-proof-dual-temperature-switch.jpg\"><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.soloonactuators.com\/uploads\/ExS6011-T-series-explosion-proof-dual-temperature-switch.jpg\" alt=\"ExS6011-T series explosion-proof dual temperature switch\" \/><\/a><\/p>\n<p style=\"text-align: justify\">&nbsp;<\/p>\n<p style=\"text-align: justify\">III. Operating PrincipleUnder normal conditions, both TS1 and TS2 remain closed, and the actuator operates normally with power supplied.When the ambient or duct temperature exceeds the set point &rarr; TS1 or TS2 opens &rarr; actuator loses power &rarr; damper returns to the safe positionIV. Certifications &amp; Standards<\/p>\n<p style=\"text-align: justify\">The product complies with the following major standards, with a complete certification chain:<\/p>\n<p style=\"text-align: justify\">Gas environments:<\/p>\n<ul style=\"text-align: justify\">\n<li>IEC 60079-0:2017 \/ EN 60079-0:2018 &mdash; General requirements<\/li>\n<li>IEC 60079-1:2014-08 \/ EN 60079-1:2014 &mdash; Flameproof enclosure &ldquo;d&rdquo;<\/li>\n<\/ul>\n<p style=\"text-align: justify\">Dust environments:<\/p>\n<ul style=\"text-align: justify\">\n<li>IEC 60079-31:2022 \/ EN 60079-31:2014 &mdash; Enclosure &ldquo;t&rdquo; dust ignition protection<\/li>\n<\/ul>\n<p style=\"text-align: justify\">Certificates held: China Explosion-Proof Certification + ATEX + IECEx<\/p>\n<p style=\"text-align: justify\">&nbsp;<\/p>\n<p style=\"text-align: justify\">V. Typical Applications<\/p>\n<table>\n<thead>\n<tr>\n<th>Industry<\/th>\n<th>Applications<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Oil &amp; Gas<\/td>\n<td>Refinery heater dampers, tank ventilation, oil\/gas recovery systems<\/td>\n<\/tr>\n<tr>\n<td>Petrochemical<\/td>\n<td>Drying equipment, VOCs treatment system dampers<\/td>\n<\/tr>\n<tr>\n<td>Dust-prone industries<\/td>\n<td>Grain\/feed processing, pharmaceuticals, paint shops, metal powder handling<\/td>\n<\/tr>\n<tr>\n<td>New energy<\/td>\n<td>Lithium battery plants, hydrogen facility ventilation<\/td>\n<\/tr>\n<tr>\n<td>Environmental engineering<\/td>\n<td>RTO\/RCO waste gas treatment, waste incineration ventilation<\/td>\n<\/tr>\n<tr>\n<td>Marine &amp; offshore<\/td>\n<td>Hazardous-area ventilation on tankers\/drilling platforms<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: justify\">In a nutshell: Wherever there are explosion-proof dampers, an explosion-proof temperature switch is needed for overtemperature protection.<\/p>\n<p style=\"text-align: justify\">&nbsp;<\/p>\n<p style=\"text-align: justify\">VI. Selection Guide<\/p>\n<table>\n<thead>\n<tr>\n<th>Operating Condition<\/th>\n<th>Recommended Model<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Low normal duct temperature, early warning required<\/td>\n<td>72\u2103<\/td>\n<\/tr>\n<tr>\n<td>High-temperature processes, hot-air recirculation, drying\/curing equipment<\/td>\n<td>150\u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: justify\">Selection principle: The actuation temperature should be higher than the normal operating temperature but lower than the maximum temperature the equipment can withstand.<\/p>\n<p style=\"text-align: justify\">&nbsp;<\/p>\n<p style=\"text-align: justify\">VII. Installation &amp; Safety Instructions<\/p>\n<p style=\"text-align: justify\">&nbsp;<\/p>\n<p style=\"text-align: justify\">Installation requirements:<\/p>\n<ul style=\"text-align: justify\">\n<li>Must be installed by trained or experienced personnel<\/li>\n<li>Never perform work with power on; strictly follow installation procedures<\/li>\n<li>Cable glands must bear the corresponding explosion-proof certification<\/li>\n<li>Tightening torque for flameproof joints: 5.5 Nm<\/li>\n<\/ul>\n<p style=\"text-align: justify\">&nbsp;<\/p>\n<p style=\"text-align: justify\">Safety warnings:<\/p>\n<ul style=\"text-align: justify\">\n<li>Never open the cover while energized; do not disassemble or modify without authorization<\/li>\n<li>Wait 25 minutes after power-off before opening the cover; wipe with a wet cloth (anti-static) when opening<\/li>\n<li>Flameproof mating surfaces must not be repaired or modified by the user<\/li>\n<li>Contains electrical\/electronic components &mdash; dispose of as e-waste per local regulations; do not discard as ordinary waste<\/li>\n<li>Not applicable in areas affected by charge generation, mechanical friction, separation processes, electron emission, or pneumatic dust conveying<\/li>\n<\/ul>\n<p style=\"text-align: justify\">&nbsp;<\/p>\n<p style=\"text-align: justify\">VIII. Why Choose the ExS6011-T Series?<\/p>\n<table>\n<thead>\n<tr>\n<th>Advantage<\/th>\n<th>Value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Triple international certifications<\/td>\n<td>One product, global use &mdash; simplified procurement<\/td>\n<\/tr>\n<tr>\n<td>Two temperature options<\/td>\n<td>Adapts to low- or high-temperature processes<\/td>\n<\/tr>\n<tr>\n<td>IP66 protection<\/td>\n<td>Suited for outdoor, dusty, humid, and harsh conditions<\/td>\n<\/tr>\n<tr>\n<td>Universal power supply<\/td>\n<td>Compatible with various supply voltages worldwide<\/td>\n<\/tr>\n<tr>\n<td>Long-life design<\/td>\n<td>Manual operation &ge; 1,000 cycles &mdash; reduced maintenance<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: justify\">Wherever there are explosion-proof dampers, the ExS6011-T explosion-proof temperature switch has its place.<\/p>\n<p style=\"text-align: justify\">Welcome to contact us for samples or technical selection support.<\/p>\n<p style=\"text-align: justify\">About Us<\/p>\n<p style=\"text-align: justify\">Established in April 2000, Soloon Controls (Beijing) Co. Ltd. is a dedicated manufacturer specializing in the research, development,and production of high-performance actuators.<\/p>\n<p class=\"caps\"><span style='font-size:18px !important'>Media Contact<\/span><br \/><strong>Company Name:<\/strong> <a rel=\"nofollow\" href=\"https:\/\/www.abnewswire.com\/companyname\/soloonactuators.com_195431.html\">SOLOON CONTROLS (BEIJING) CO., LTD.<\/a><br \/><strong>Contact Person:<\/strong> Media Relations<br \/><strong>Email:<\/strong> <a rel=\"nofollow\" href=\"https:\/\/www.abnewswire.com\/email_contact_us.php?pr=exs6011t-series-explosionproof-dual-temperature-switch-advances-industrial-temperature-control\">Send Email<\/a><br \/><strong>Country:<\/strong> China<br \/><strong>Website:<\/strong> <a rel=\"nofollow noopener\" href=\"https:\/\/www.soloonactuators.com\/\" target=\"_blank\">https:\/\/www.soloonactuators.com\/<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.abnewswire.com\/press_stat.php?pr=exs6011t-series-explosionproof-dual-temperature-switch-advances-industrial-temperature-control\" alt=\"\" width=\"1px\" height=\"1px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Beijing China-September 22, 2026 I. Product Positioning The ExS6011-T series explosion-proof dual temperature switch is specifically designed for workplaces with explosive hazardous gases, vapors, or combustible dust, such as oil<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"_links":{"self":[{"href":"https:\/\/www.olympiajournal.com\/news\/wp-json\/wp\/v2\/posts\/615070"}],"collection":[{"href":"https:\/\/www.olympiajournal.com\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.olympiajournal.com\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.olympiajournal.com\/news\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.olympiajournal.com\/news\/wp-json\/wp\/v2\/comments?post=615070"}],"version-history":[{"count":0,"href":"https:\/\/www.olympiajournal.com\/news\/wp-json\/wp\/v2\/posts\/615070\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.olympiajournal.com\/news\/wp-json\/wp\/v2\/media?parent=615070"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.olympiajournal.com\/news\/wp-json\/wp\/v2\/categories?post=615070"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.olympiajournal.com\/news\/wp-json\/wp\/v2\/tags?post=615070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}